A novel damage index for fatigue damage detection in a laminated composites using lamb waves

Loading...
Thumbnail Image
Date
2015
Journal Title
Journal ISSN
Volume Title
Publisher
University of Alabama Libraries
Abstract

A well-established structural health monitoring (SHM) technique, the Lamb wave based approach, is used for fatigue damage identification in a laminated composite. A novel damage index, ‘normalized correlation moment’ (NCM) which is composed of the nth moment of the cross correlation of the baseline and comparison waves, was used as damage index for monitoring damage in composites and compared with the signal difference coefficient (SDC) which is one of the most commonly used damage indices. Composite specimens were fabricated by the hand layup method by followed by compression. Piezo electric disks mounted on composite specimens were used as actuators and sensors. Three point bending fatigue tests were carried out on an intact composite laminate and a delaminated composite laminate with [06/904/06] orientation. Finite element analysis was performed to test the validity of SDC and NCM for fatigue damage.

Description
Electronic Thesis or Dissertation
Keywords
Aerospace engineering, Mechanical engineering